Lancaster Laboratories
Where
quality is a science.
Lancaster
Laboratories Sample No. MB 3352462
Collected: n.a. Account Number: 01907
Submitted: 03/30/2000 09:10 CitroBio, Inc.
Reported: 09/22/00 at 04:05 PM 7614 301 Boulevard
Discard: 10/8/00 Sarasota FL 34243
5% Solution
of CitroBio
CAT
No. Analysis
Name CAS Number Result Quantitation Units Factor 09189 Biological Testing
n.a.
See Below n.a.
Using a
proposal designed to evaluate CitroBio 5% against Listeria monocytogenes
on fish the test was performed as follows:
1. Six
haddock fillets were purchased
2. Prior to testing, three of the six were swabbed for L. monocytogenes.
3. The surface of the six fillets were inoculated with L. monocytogenes
(ATCC 19111)
and allowed a 1 hour contact time.
4. The surface of three of the fillets was flooded with a 1 ounce/gallon
solution of the CitroBio material.
5. After 5 minutes of contact time the six fillets were swabbed and
evaluated for the presence of L. monocytogenes.
Results
a. The
three initial swabs were negative for Listeria.
b. The
inoculated control samples were positive for L. monocytogenes.
c. The
treated samples were positive for L. monocytogenes.
Based
on these results it was decided that a zone of inhibition study be performed
to determine what level of CitroBio was effective. 1. MOX agar which
is used to propagate L. monocytogenes was selected as the test medium.
2. A 24 hour culture was used to inoculate the plate.
i. The
plates were allowed to dry.
4. A blank
was included to be sure that= there was no interference from other sources
5. The
test solution was prepared at 1, 2, 3, 4, and 5 ounces / gallon
6. Discs
that were 12 mm in diameter were used. They were saturated with the
different solutions and spotted on the plates. This was done in duplicate
on different plates.
7. The
plates were incubated for 24 hours and the size of the zones of inhibition
measured and recorded.
8. Listed
below are the results:
9. Based
ib the information generated, at the levels of 2oz to 5oz the activity
against L Monocytogenes was effective at these levels.
Lancaster Laboratories
Where quality
is a science.
Page 2
of 2 Lancaster Laboratories Sample No. MB3352462
Collected:
n.a. Account Number: 01907
Submitted:
03/30/2000 09:10 CitroBio, Inc. Reported: 09/22/00 at 04:05 PM
Discard:
10/8/00 Sarasota FL
5% Solution
of CitroBio As Received
CAT As
Received
No. Analysis
Name CAS Number Result
A. Blank
No Zone Disc size 12 mm
B. 1 ounce
/ gallon Trace,Trace
C. 2 ounces/gallon
14 mm, 15 mm
D. 3 ounces/gallon
17 mm, 17 mm
E. 4 ounces/gallon
21 mm, 22 mm
F. 5 ounces/gallon
23 mm, 23 mm
Lancaster
Laboratories
M E M B E R 2425 New Holland Pike
ACIL PO Box 12425
Lancaster, PA 17605-2425
717-656-2300 Fax: 717-656-2681
|
CitroBio, Inc.
7614 15th Street East Sarasota FL 34243
1.800.332.1647
Citribio uses FDA/GRAS approved ingredients! |
Send mail to
Webmaster@citrobio.com with questions or comments about this site.
Copyright �